Permissions

Permissions

The plugin uses NetBox's own object permissions — no plugin-specific roles. Grant them to groups in Admin → Permissions, with constraints if you want them scoped (per site, per tenant). This page lists what each kind of user needs.

Reviewer — sees plans, changes nothing

Object types Actions
netbox_rack_design · design, design group, design placement, planned power feed, design rack power, planned rack, template, template group, template placement view
netbox_rack_design · design apply view
dcim · site, location, rack, device, device type, device role, power panel, power feed, power port, power outlet view

With view rights a user can open design pages, lists, the projected elevations and the editor itself; saving in the editor needs the planner rights below. For a strictly read-only audience, point them at Elevations rather than the editor.

Planner — edits designs

Everything a reviewer has, plus:

Object types Actions Why
design, design placement add, change, delete Creating designs; the editor's Save writes placements
planned power feed, design rack power add, change, delete The rack Power dialog (planned feeds, copy from rack, overrides)
planned rack add, change, delete Create rack in the editor
template, template group, template placement add, change, delete Save as template, template groups (omit to let planners only use templates)
favorite set, favorite device type, hidden design rack, hidden design chassis add, change, delete The user's own favorites and rack/chassis visibility — per-user state, safe to grant broadly

Only view on DCIM is needed for planning: a planner never writes to DCIM.

Whoever applies

Applying writes real DCIM objects with the applying user's own permissions — there is no service account (see Applying a design). On top of change on the design:

Object types Actions Needed when
dcim.device add, change, delete Always: planned devices are created, updated, flagged; a re-apply may delete one whose placement is gone
dcim.rack add, change The design holds planned racks (created, or adopted)
dcim.powerfeed add The design holds planned power feeds
dcim.cable add Planned feeds get their PDUs cabled

Each object is checked in the site it lands in, so on a multi-site design the user needs these rights in every site the design touches. Anything missing is reported on the Apply page as a problem, and nothing is written.

Scoping with constraints

Design permissions scope by site through the design's sites:

{"sites__slug__in": ["ams1", "ams2"]}

Placements, planned feeds and rack power scope through their design: {"design__sites__slug__in": [...]}; planned racks through their location: {"location__site__slug__in": [...]}. (Designs used to have a single site; constraints written as {"site__slug": ...} must be updated to sites__….)